novascan_ozone_cleaner

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Last revisionBoth sides next revision
novascan_ozone_cleaner [2022/08/22 22:21] bdincaunovascan_ozone_cleaner [2023/01/05 20:42] – [Novascan Ozone Cleaner] haley
Line 2: Line 2:
  
  
-^             Novascan Ozone Cleaner                                    ^+^             Ozone Cleaner                                    ^
 |  {{ :tools:novascanozonecleaner:novascan_ozone_cleaner.jpg?nolink&200 |}}                              | |  {{ :tools:novascanozonecleaner:novascan_ozone_cleaner.jpg?nolink&200 |}}                              |
-| **Tool Type:**                  UV Ozone Chamber                           +| **Tool Type:**                  Surface treatment                         
-| **Location:**                   Elings 3430                          |+| **Location:**                   Microfluidics Lab                         |
  
  
-|  **Supervisor**        |  **Tool Lead**  |      +| **Description:**                Ozone chamber with UV bulb and adjustable platform.                           |
-|  Brian Dincau        |  Brian Dincau +
-|  (805) 724-0426‬          (805) 724-0426‬   | +
-|  workshop-manager@cnsi.ucsb.edu  |  workshop-manager@cnsi.ucsb.edu +
- +
-| **Description:**                Chamber with UV bulb and adjustable platform.                           |+
 | **Manufacturer:**               Novascan                           | | **Manufacturer:**               Novascan                           |
  
Line 25: Line 20:
 ---- ----
  
-===== Detailed Specifications =====+===== Safety Concerns =====
  
-Include: Platform volume (about 8" x 8" x 8")+Ultraviolet Radiation Hazard - Due to a device interlock, the UV bulb is only on when the chamber is closed.\\ 
 +Pinching Hazard - Careful when closing the lid to avoid pinching fingers.\\ 
 +Electrical Hazard - No liquids allowed.
  
 ---- ----
  
-===== Safety Concerns =====+===== Training Documentation =====
  
-Ultraviolet Light Hazard - Due to a device interlock, the UV bulb is only on when the chamber is closed. +[[ozone_cleaner_sop|Ozone Cleaner Training SOP]]
-Pinching Hazard - Careful when closing the lid to avoid pinching fingers+
  
 ---- ----
  
-===== Operating Procedures =====+===== Detailed Specifications =====
  
-1) Open the chamber lid. \\ +Platform volume - about 9" x 9" x 4" \\ 
-2) Adjust the sample platform and place your sample. Ensure that your sample has ample clearance above, to avoid crushing the expensive UV bulb. (Use the nearby ruler with tape indicator). \\ +Lamp type - mercury vapor \\ 
-3) Set the timer to begin exposure. \\ +No temperature control \\
-4) Exposure is complete when time ends. Open the lid, remove your sample, then close the lid.+
  
 ---- ----
 +
  
 ===== Reference Documentation ===== ===== Reference Documentation =====
Line 54: Line 50:
  
 ----- -----
-===== Training Documentation ===== 
  
-{{ :tools:novascanozonecleaner:novascan_uv_ozone_signin.docx |}} 
- 
----- 
  
novascan_ozone_cleaner.txt · Last modified: 2023/07/11 18:23 by rylin