 ===== Safety Concerns ===== ===== Safety Concerns =====
-**High Heat Hazard** - Never operate furnace near combustibles. Always wear thermally insulated gloves when transferring samples out of the furnace. // +**High Heat Hazard** - Never operate furnace near combustibles. Always wear thermally insulated gloves when transferring samples out of the furnace. \\ 
  
-**Pinching Hazard** - Be careful when closing the top assembly, known as the muffle. It's possible to pinch your fingers/hands when closing. It is also possible to damage you sample if any part of your sample hangs off of the interior platform. // +**Pinching Hazard** - Be careful when closing the top assembly, known as the muffle. It's possible to pinch your fingers/hands when closing. It is also possible to damage you sample if any part of your sample hangs off of the interior platform. \\ 
  
 ---- ----
  
 ===== Operating Procedures ===== ===== Operating Procedures =====
-See attached operating manual for detailed operation. // +See attached operating manual for detailed operation. \\ 
  
-General Operation //  +General Operation \\  
-1) Set up the furnace on an appropriate counter top. Make any desired vacuum or nitrogen connections.//  +1) Set up the furnace on an appropriate counter top. Make any desired vacuum or nitrogen connections.\\  
-2) Plug the furnace in and power on.//  +2) Plug the furnace in and power on.\\  
-3) Set up your desired program.//  +3) Set up your desired program.\\  
-4) Open the muffle by pressing the double up arrow.//  +4) Open the muffle by pressing the double up arrow.\\  
-5) Load your sample onto the platform, ensuring that none of you sample hangs over the edge.//  +5) Load your sample onto the platform, ensuring that none of you sample hangs over the edge.\\  
-6) Close the muffle and run your program.//  +6) Close the muffle and run your program.\\  
-7) When finished, move the muffle up, remove your sample, and power down the furnace.// +7) When finished, move the muffle up, remove your sample, and power down the furnace.\\ 
  
 ---- ----
  
 ===== Detailed Specifications ===== ===== Detailed Specifications =====
-See attached manual for complete specifications//  +See attached manual for complete specifications\\  
-//  +\\  
-Chamber Platform Diameter: 4 in (10 cm) +Chamber Platform Diameter: 4 in (10 cm)\\  
-Chamber Height: 2.5 in (6.3 cm) +Chamber Height: 2.5 in (6.3 cm)\\  
-Max Temp: 1200 C+Max Temp: 1200 C\\ 
  
 ----- -----
Line 51: Line 51:
  
 ===== Reference Documentation ===== ===== Reference Documentation =====
 +{{:Tools:neytech_man.pdf | Operation Manual}}
  
 ----- -----