neytech_qex_furnace
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
neytech_qex_furnace [2023/01/31 00:07] – bdincau | neytech_qex_furnace [2023/01/31 00:13] (current) – [Reference Documentation] bdincau | ||
---|---|---|---|
Line 20: | Line 20: | ||
===== Safety Concerns ===== | ===== Safety Concerns ===== | ||
- | **High Heat Hazard** - Never operate furnace near combustibles. Always wear thermally insulated gloves when transferring samples out of the furnace. | + | **High Heat Hazard** - Never operate furnace near combustibles. Always wear thermally insulated gloves when transferring samples out of the furnace. |
- | **Pinching Hazard** - Be careful when closing the top assembly, known as the muffle. It's possible to pinch your fingers/ | + | **Pinching Hazard** - Be careful when closing the top assembly, known as the muffle. It's possible to pinch your fingers/ |
---- | ---- | ||
===== Operating Procedures ===== | ===== Operating Procedures ===== | ||
- | See attached operating manual for detailed operation. | + | See attached operating manual for detailed operation. |
- | General Operation | + | General Operation |
- | 1) Set up the furnace on an appropriate counter top. Make any desired vacuum or nitrogen connections.// | + | 1) Set up the furnace on an appropriate counter top. Make any desired vacuum or nitrogen connections.\\ |
- | 2) Plug the furnace in and power on.// | + | 2) Plug the furnace in and power on.\\ |
- | 3) Set up your desired program.// | + | 3) Set up your desired program.\\ |
- | 4) Open the muffle by pressing the double up arrow.// | + | 4) Open the muffle by pressing the double up arrow.\\ |
- | 5) Load your sample onto the platform, ensuring that none of you sample hangs over the edge.// | + | 5) Load your sample onto the platform, ensuring that none of you sample hangs over the edge.\\ |
- | 6) Close the muffle and run your program.// | + | 6) Close the muffle and run your program.\\ |
- | 7) When finished, move the muffle up, remove your sample, and power down the furnace.// | + | 7) When finished, move the muffle up, remove your sample, and power down the furnace.\\ |
---- | ---- | ||
===== Detailed Specifications ===== | ===== Detailed Specifications ===== | ||
- | See attached manual for complete specifications// | + | See attached manual for complete specifications\\ |
- | // | + | \\ |
- | Chamber Platform Diameter: 4 in (10 cm) | + | Chamber Platform Diameter: 4 in (10 cm)\\ |
- | Chamber Height: 2.5 in (6.3 cm) | + | Chamber Height: 2.5 in (6.3 cm)\\ |
- | Max Temp: 1200 C | + | Max Temp: 1200 C\\ |
----- | ----- | ||
Line 51: | Line 51: | ||
===== Reference Documentation ===== | ===== Reference Documentation ===== | ||
+ | {{: | ||
----- | ----- |
neytech_qex_furnace.1675123656.txt.gz · Last modified: 2023/01/31 00:07 by bdincau