User Tools

Site Tools


thermoline_furnace

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
thermoline_furnace [2020/08/05 03:11] – [Reference Documentation] furstthermoline_furnace [2023/01/30 22:34] (current) bdincau
Line 1: Line 1:
 ====== Thermoline 1315M Furnace ====== ====== Thermoline 1315M Furnace ======
  
-The following is a sample image that can be inserted by clicking on the small picture frame icon in the edit bar. 
  
-^                   Thermoline 1315M Furnace                            ^+^                   Thermoline Furnace                            ^
 |   {{ :tools:thermolinefurnace:thermoline_furnace.jpg?nolink&200 |}}                                                                    |   {{ :tools:thermolinefurnace:thermoline_furnace.jpg?nolink&200 |}}                                                                   
-| **Tool Type:**                  "TEXT HERE"                           +| **Tool Type:**                  Box Furnace                          
-| **Location:**                   "TEXT HERE"                           |+| **Location:**                   Microfluidics Lab                           |
  
  
- **Supervisor**         **Tool Lead**       +| **Description:**                Small High-Temperature (1000 C) Box Furnace                          | 
-|  David Bothman          "WW Name" +| **Manufacturer:**               Thermoline                          
-|  (805) 893-4125        |  (###) ###-#### +
-|  bothman@cnsi.ucsb.edu  |  "WW Email"  |+
  
-| **Description:**                "TEXT HERE"                           | 
-| **Manufacturer:**               "TEXT HERE"                           | 
  
----- 
  
 ===== About ===== ===== About =====
  
-Insert Text Here! +From the manufacturer: The furnace chamber is heated by a single three section resistant heater which is embedded in a refractory material. The chamber is 
 +insulated with a ceramic fiber insulation. The 
 +temperature is controlled by an electronic control. The temperature is measured by a thermocouple and is registered on a digital display. For 
 +safety, door switches are incorporated to 
 +remove power from the heating elements when 
 +the door is opened. The furnace is supported by 
 +the control section which also houses the electrical connections.
 ---- ----
  
-===== Detailed Specifications ===== +===== Safety Concerns ===== 
- +  * High Temperature 
-Insert Text Here!+  * No combustibles or hazardous materials 
 +  * Thermally insulating gloves must be worn when working with hot items. 
 +  * Do not use to heat food.  
 +  * Never heat a sealed container.  
 +  * Do not operate the furnace if it is damaged, or is not working properly. Please place a note on the oven to alert other users, and notify laboratory staff of the problem.  
 +  * **Double containment is required for heating containers of liquid to prevent leaked material from contaminating the oven. This is especially true when heating PDMS molds.**
  
 ---- ----
  
-===== Safety Concerns =====+===== Operating Procedures =====
  
-Insert Text Here! 
  
-----+1) Plug in the furnace and power on. \\  
 +2) Set the desired temperature using the up/down arrow buttons on the controller. \\  
 +3) Locate at pair of thermally insulated gloves, usually near the convention ovens. \\  
 +4) Once the desired temperature is reached, place your item(s) in the furnace while wearing insulated gloves. Remember, all liquids must be double contained so that if they spill, the oven remains clean. \\  
 +5) If performing multiple steps, adjust the temperature when needed. \\  
 +6) When finished, power off and unplug the furnace. Close the door and leave a note if the furnace is still hot when you leave.
  
-===== Operating Procedures =====+-----
  
-Insert Text Here!+===== Detailed Specifications ===== 
 +  * Chamber dimensions: 4” W x 3.75” H x 4.5” D (10.2 x 9.5 x 11.4 cm) 
 +  * Temperature ranges: 100C-982C for continuous use, or 982C-1100C for intermittent use. Continuous use is operating the furnace for more than three straight hours, and intermittent use is operating the furnace for less than three hours. 
 + 
 +-----
  
----- 
  
 ===== Reference Documentation ===== ===== Reference Documentation =====
Line 50: Line 62:
  
 ----- -----
-===== Training Documentation ===== 
  
-Insert Text Here! 
----- 
  
thermoline_furnace.1596597112.txt.gz · Last modified: 2020/08/05 03:11 by furst