sca_naoh_bath
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
sca_naoh_bath [2020/10/08 17:05] – [Training Documentation] furst | sca_naoh_bath [2023/01/06 01:31] (current) – [SCA 1200 HT NaOH Parts Bath] haley | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | ====== SCA 1200 HT NaOH parts bath ====== | + | ====== SCA 1200 HT NaOH Parts Bath ====== |
- | ^ | + | ^ NaOH Bath ^ |
| | | | ||
- | | **Tool Type: | + | | **Tool Type: |
- | | **Location: | + | | **Location: |
- | | **Supervisor** | ||
- | | David Bothman | ||
- | | (805) 893-4125 | ||
- | | bothman@cnsi.ucsb.edu | ||
- | | **Description: | + | | **Description: |
- | | **Manufacturer: | + | | **Manufacturer: |
+ | Last updated 1/5/23 Haley | ||
---- | ---- | ||
===== About ===== | ===== About ===== | ||
- | This tool is used to dissolve the support filament printed by the F270 FDM 3D printer. | + | This tool is used to dissolve the support filament printed by the Stratysys |
- | ---- | + | |
- | + | ||
- | ===== Detailed Specifications ===== | + | |
- | + | ||
- | Insert Text Here! | + | |
---- | ---- | ||
Line 30: | Line 22: | ||
===== Safety Concerns ===== | ===== Safety Concerns ===== | ||
- | This tool makes use of a heated solvent! A lab coat, face shield, and nitrile gloves must be wore by the user whenever the SCA 1200 HT is to be opened to protect | + | This tool makes use of a heated solvent! A lab coat, face shield, and nitrile gloves must be wore by the user whenever the SCA 1200 HT is to be opened to protect |
---- | ---- | ||
Line 37: | Line 30: | ||
- Remove completed part on build tray from F270 3D printer | - Remove completed part on build tray from F270 3D printer | ||
- Remove part from build tray, making sure to scrape build tray free of ALL residue | - Remove part from build tray, making sure to scrape build tray free of ALL residue | ||
- | - Dawn lab coat, nitrile gloves, and a face shield | + | - Put on a lab coat, nitrile gloves, and a face shield |
- Open lid on SCA 1200 HT | - Open lid on SCA 1200 HT | ||
- Slowly lift large basket, allow time to for excess solution to drip back into SCA 1200HT \\ NOTE: If solution rises above specific level alarm will sound, this is common when lifting or lowering basket and means you're moving too fast! | - Slowly lift large basket, allow time to for excess solution to drip back into SCA 1200HT \\ NOTE: If solution rises above specific level alarm will sound, this is common when lifting or lowering basket and means you're moving too fast! | ||
Line 47: | Line 40: | ||
- Follow steps 3-6 to remove part, followed by steps 8 to replace basket | - Follow steps 3-6 to remove part, followed by steps 8 to replace basket | ||
- Part should be allowed to drip, before being rinsed in sink with plenty of warm water | - Part should be allowed to drip, before being rinsed in sink with plenty of warm water | ||
+ | |||
---- | ---- | ||
- | ===== Reference Documentation ===== | ||
- | {{:tools: | + | ===== Detailed Specifications ===== |
+ | * Available Temperatures: 50, 60, 70, 85 degrees C | ||
+ | * Auto overfill alarm | ||
+ | * 46.3 L tank | ||
- | {{: | ||
---- | ---- | ||
- | ===== Training | + | |
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | ===== Reference | ||
[[f270_sop|FDM Training SOP]] | [[f270_sop|FDM Training SOP]] | ||
+ | |||
+ | {{: | ||
+ | |||
+ | |||
---- | ---- |
sca_naoh_bath.1602176741.txt.gz · Last modified: 2020/10/08 17:05 by furst