====== FormCure UV Curing Station ====== | ====== FormCure UV Curing Station ====== | ||
- | ^ | + | ^ |
| {{ : | | {{ : | ||
- | | **Tool Type: | + | | **Tool Type: |
- | | **Location: | + | | **Location: |
- | | **Supervisor** | ||
- | | David Bothman | ||
- | | (805) 893-4125 | ||
- | | bothman@cnsi.ucsb.edu | ||
- | | **Description: | ||
- | | **Manufacturer: | ||
+ | | **Description: | ||
+ | | **Manufacturer: | ||
+ | |||
+ | Last updated 1/5/23 Haley | ||
---- | ---- | ||
===== About ===== | ===== About ===== | ||
- | Insert Text Here! | + | After your FormLabs print has gone through the FormWash, the resin should be cured in the FormCure, a UV curing chamber. Each resin has a specific hardening curve that can be found within the reference material. This will help you indicate the ideal time and temperature to be set on the FormCure. |
---- | ---- | ||
- | ===== Detailed Specifications | + | ===== Safety Concerns |
- | Insert Text Here! | + | * Allow at least half an hour for IPA to evaporate before placing part in FormCure |
+ | * Allow time for the Form Cure to cool off before removing parts | ||
+ | * Do not operate form cure with lid open | ||
---- | ---- | ||
- | ===== Safety Concerns | + | ===== Operating Procedures |
- | Insert Text Here! | + | - Any part to be cured needs to be washed in the FormWash with IPA BEFORE being placed in the form cure. Supports can be removed before or after curing process. |
+ | - Wait 30 minutes after washing to allow all remaining IPA to evaporate | ||
+ | - Check the reference material for selected resin to determine ideal time and temperature for curing | ||
+ | - Use the dial on the front of the FormCure to set time and temperature | ||
+ | - Place part within the FormCure-> | ||
- | ---- | + | ----- |
- | ===== Operating Procedures | + | ===== Detailed Specifications |
+ | * Max cure temp: 80 degrees C | ||
+ | * Light: 39W total drawn by 13 405 nm LEDs | ||
- | Insert Text Here! | ||
---- | ---- | ||
+ | |||