 =====Form 2/3 Training SOP===== =====Form 2/3 Training SOP=====
-Last edited: Furst (8/28/20)+Last edited: Haley (9/19/22)
  
-Instructor+====Training Checklist:==== 
- +  *Safetypersonal protective equipment, avoid eye contact with laser, avoid contaminating areas with resin 
-Date+  *Job Setup 
- +    *On the computer: PreForm software, file orientation, adjusting supports, record in FBS, selected material and version match the resin type loaded in the desired printer 
-{| style="" +    *Printerconfirm print, avoid any spills 
-|+ Attendees+  *Using the Form Wash: transport part and build platform, wash and allow time for IPA to evaporate 
-! +  *Using the Form Cure: release part from build platformadjust curing settings depending on resin 
- +  *Post Processing: break support materialabrasives to remove marks left by touchprints 
-+  *Replacing an empty resin cartridge with a full one of the same type 
-Name (LastFirst) +    *Remove and replace cartridges 
-+    *Avoid spills  
-Group or Company +    *Mark off new build tanks when new resin cartridge is put into rotation 
-+  *Switching a printer from one type of resin to another 
-Signature (FirstLast) +    *Remove build platform, resin cartridge, and resin tank 
-|- +    *Cover resin tank 
-|1 +    *Insert resin tank, lock wiper blade, insert resin cartridge, replace build platform 
-| +    *Mark off new build tanks when new resin cartridge is put into rotation 
-| +  *Maintenance: clean resin tank interior, filter resin, cleaning tank window
-| +
-|- +
-|2 +
-| +
-| +
-+
-|- +
-|3 +
-+
-+
-+
-|- +
-|4 +
-+
-+
-+
-|- +
-|5 +
-+
-+
-+
-|- +
-|6 +
-+
-+
-+
-|} +
------+
  
 ====Overview:==== ====Overview:====
Line 99: Line 71:
  
 ====Using the Form Wash:==== ====Using the Form Wash:====
-  * Transport the part and build platform in the container to Fume Hood #4 in Elings 2442.+  * Transport the part and build platform in the container found  in the fume hood.
   * Wear a lab coat and safety goggles, as the Form Wash contains IPA.   * Wear a lab coat and safety goggles, as the Form Wash contains IPA.
-  *  Press ‘Open’+  * Press ‘Open’
   * Slide the build platform into place   * Slide the build platform into place
-  * Adjust the wash time to 10 minutes. For times for resins other than flexible and clear, consult the webpage “Form Wash Time Settings” through the Formlabs website.+  * Adjust the wash time to 15 minutes (20 for flexible & durable)
   * Press ‘Start’   * Press ‘Start’
   * After the washing is over, press ‘Open’ and remove the build platform. Place it in the container.   * After the washing is over, press ‘Open’ and remove the build platform. Place it in the container.
Line 111: Line 83:
 **Using the Form Cure:**\\ **Using the Form Cure:**\\
   * Release the part from the build platform:   * Release the part from the build platform:
-      * Place build platform on the removal jig. Tools are in the Fume Hood #4 in Elings 2442.+      * Place build platform on the removal jig. 
       * Slide a removal tool under the angled edge of the part’s base to separate it from the build platform.       * Slide a removal tool under the angled edge of the part’s base to separate it from the build platform.
   * Lift the cover of the Form Cure. Place the part in the center of the turntable.   * Lift the cover of the Form Cure. Place the part in the center of the turntable.
Line 181: Line 153:
     * Never use IPA on the acrylic tank window (it will cause cracks).     * Never use IPA on the acrylic tank window (it will cause cracks).
     * If dust, fingerprints, and/or contamination are present, clean the clear acrylic tank window with NOVUS No. 1 and a clean microfiber cloth. The clear acrylic tank window is located on the underside of the resin tank. Apply 1-2 full sprays of NOVUS No. 1, and wipe using long, sweeping strokes top to bottom and across the tank window. Fold the microfiber cloth after each swipe to prevent dust and debris from scratching the acrylic.     * If dust, fingerprints, and/or contamination are present, clean the clear acrylic tank window with NOVUS No. 1 and a clean microfiber cloth. The clear acrylic tank window is located on the underside of the resin tank. Apply 1-2 full sprays of NOVUS No. 1, and wipe using long, sweeping strokes top to bottom and across the tank window. Fold the microfiber cloth after each swipe to prevent dust and debris from scratching the acrylic.
- 
------ 
-====Form 2/3 Quick Review==== 
-Tool Lead:    \\ 
-Contact: andrewfurst@ucsb.edu      \\ 
-====Safety Concern====  
-  * Lab coat and gloves must me used when handling resin  
-  * Anything with uncured resin must be transported within a container to avoid spilling  
- 
-====Safe Operation Procedures Review==== 
-  - Check resin cartridge and tank, make sure build material matches and is desired material. 
-  - If resin is not desired material, disconnect wiper at build tank, remove build plate by sliding towards front of fume hood. Remove cartridge, cap valve on bottom and close valve on top of cartridge. Replace build tank, wiper, and cartridge with desired material.  
-  - Launch Preform on Ultimaker computer 
-  - Import desired STL 
-  - Select "one click print" in the top left corner menu, change position, orientation, resolution and support as desired (note: that Preform will report on print ability of model, changing part rotation can affect print ability. 
-  - Select print (orange button) from top left menu 
-  - Select desired printer 
-  - Press button on Formlabs printer to start print  
- 
-====Post Processing==== 
-  - Excess resin should be removed from the build tray and part with IPA over a waste container.  
-  - Place build tray and part in the Form Wash for 20 to 30 minuets (part can be placed individually within basket if necessary 
-  - Allow 30 minuets for IPA to evaporate before placing part in Form Cure 
-  - Set Form Cure time and temperature based on resin type, place part within form cure, wait for time to elapse 
- 
-====Maintenance==== 
-  * Switching resin types 
-    * Close breather valve on resin cartridge 
-    * Remove the resin cartridge by pulling straight up on the handle behind the form labs printers  
-    * Cap the cartridge valve using the included orange tap and cap 
-    * Remove the wiper by pulling straight out towards the front of the fume hood.  
-    * Pull the resin tray out of the printer by pulling firmly straight out toward you 
-    * Lift the wiper and resin tray out simultaneously, and carefully place on resin shelf within fume hood. 
-    * Cover resin tray with black plastic cover and label 
-    * Replace resin tray with clean or desired resin tank. Push tank and wiper firmly back toward the Form 2/3 until it clicks into place  
-    * Replace resin cartridge and open valve 
- 
- 
  