sae_battery_segment_manufacture_assembly
                Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| sae_battery_segment_manufacture_assembly [2023/06/06 18:55] – Battery segments wei | sae_battery_segment_manufacture_assembly [2023/06/06 18:58] (current) – wei | ||
|---|---|---|---|
| Line 60: | Line 60: | ||
| ====Machining of insulation panels==== | ====Machining of insulation panels==== | ||
| - | - Fixture panels, program cam, and set up tools on ShopBot Router referencing [[http:// | + | - Fixture panels, program cam, and set up tools on ShopBot Router referencing [[http:// | 
| + | {{: | ||
| *Set up vacuum attachment and wear masks to minimize inhalation of fine fiberglass particles | *Set up vacuum attachment and wear masks to minimize inhalation of fine fiberglass particles | ||
| - File edges of panels to remove sharp glass fibers | - File edges of panels to remove sharp glass fibers | ||
| ====Assembly of Enepaq modules within insulation==== | ====Assembly of Enepaq modules within insulation==== | ||
| - | - Insert modules with correct polarities and use epoxy to bond base and side panels of segment {{: | + | - Insert modules with correct polarities and use epoxy to bond base and side panels of segment | 
| + | {{: | ||
| - **Wear proper PPE (listed in safety considerations section); those without PPE should remain five feet away** and connect modules together using bolts and busbars | - **Wear proper PPE (listed in safety considerations section); those without PPE should remain five feet away** and connect modules together using bolts and busbars | ||
| * **Cover work surface and ground with electrically insulating mat and use insulated tools** | * **Cover work surface and ground with electrically insulating mat and use insulated tools** | ||
| Line 71: | Line 73: | ||
| * Attach temperature sensing wires to module xr connector | * Attach temperature sensing wires to module xr connector | ||
| - Route wires through holes in top panel | - Route wires through holes in top panel | ||
| - | - Connect voltage taps carefully and avoid short circuiting any modules {{: | + | - Connect voltage taps carefully and avoid short circuiting any modules | 
| - | - Bond top panels to enclose segment | + | {{: | 
| + | - Bond top panels to enclose segment | ||
| + | {{: | ||
sae_battery_segment_manufacture_assembly.1686077753.txt.gz · Last modified: 2023/06/06 18:55 by wei
                
                