This tool is used to dissolve the support filament printed by the Stratysys F270 FDM 3D printer. Parts can be loaded into the main bucket or suspended in a smaller cage during the support removal process. | This tool is used to dissolve the support filament printed by the Stratysys F270 FDM 3D printer. Parts can be loaded into the main bucket or suspended in a smaller cage during the support removal process. | ||
- | ---- | ||
- | |||
- | ===== Detailed Specifications ===== | ||
- | * Available Temperatures: | ||
- | * Auto overfill alarm | ||
- | * 46.3 L tank | ||
- | |||
---- | ---- | ||
Line 28: | Line 22: | ||
===== Safety Concerns ===== | ===== Safety Concerns ===== | ||
- | This tool makes use of a heated solvent! A lab coat, face shield, and nitrile gloves must be wore by the user whenever the SCA 1200 HT is to be opened to protect | + | This tool makes use of a heated solvent! A lab coat, face shield, and nitrile gloves must be wore by the user whenever the SCA 1200 HT is to be opened to protect |
---- | ---- | ||
Line 35: | Line 30: | ||
- Remove completed part on build tray from F270 3D printer | - Remove completed part on build tray from F270 3D printer | ||
- Remove part from build tray, making sure to scrape build tray free of ALL residue | - Remove part from build tray, making sure to scrape build tray free of ALL residue | ||
- | - Dawn lab coat, nitrile gloves, and a face shield | + | - Put on a lab coat, nitrile gloves, and a face shield |
- Open lid on SCA 1200 HT | - Open lid on SCA 1200 HT | ||
- Slowly lift large basket, allow time to for excess solution to drip back into SCA 1200HT \\ NOTE: If solution rises above specific level alarm will sound, this is common when lifting or lowering basket and means you're moving too fast! | - Slowly lift large basket, allow time to for excess solution to drip back into SCA 1200HT \\ NOTE: If solution rises above specific level alarm will sound, this is common when lifting or lowering basket and means you're moving too fast! | ||
Line 46: | Line 41: | ||
- Part should be allowed to drip, before being rinsed in sink with plenty of warm water | - Part should be allowed to drip, before being rinsed in sink with plenty of warm water | ||
+ | ---- | ||
+ | ===== Detailed Specifications ===== | ||
+ | * Available Temperatures: | ||
+ | * Auto overfill alarm | ||
+ | * 46.3 L tank | ||
Line 55: | Line 54: | ||
- | ===== Reference Documentation ===== | ||
- | {{: | ||
- | {{ : | + | |
- | ---- | + | ===== Reference |
- | ===== Training | + | |
[[f270_sop|FDM Training SOP]] | [[f270_sop|FDM Training SOP]] | ||
+ | |||
+ | {{: | ||
---- | ---- |
sca_naoh_bath.txt · Last modified: 2023/01/06 01:31 by haley