Line 99: Line 99:
 ====Safe Operation of this Tool==== ====Safe Operation of this Tool====
 **Before Using the Scanner:** **Before Using the Scanner:**
 +
 Make sure that the object: Make sure that the object:
   * Is larger than 30x30x30mm (1.2x1.2x1.2in)   * Is larger than 30x30x30mm (1.2x1.2x1.2in)
Line 114: Line 115:
   - Adjust __Brightness slider__ {{:tools:einscan-sp:brightness.jpg?35|}}until no red areas are visible on the desired part   - Adjust __Brightness slider__ {{:tools:einscan-sp:brightness.jpg?35|}}until no red areas are visible on the desired part
  
-**Scanning With the Turntable:**+**Scanning With the Turntable:** \\
 {{:tools:einscan-sp:turntable_menu.jpg?200|}} {{:tools:einscan-sp:turntable_menu.jpg?200|}}
   - Check the __Use Turntable__ box and specify the number of increments (8-180 steps). The __Align Mode__ menu will appear.   - Check the __Use Turntable__ box and specify the number of increments (8-180 steps). The __Align Mode__ menu will appear.
Line 221: Line 222:
 Remove the calibration board from the stand and place in the protective drawstring bag. Remove the stand from the turntable and proceed with scanning. Remove the calibration board from the stand and place in the protective drawstring bag. Remove the stand from the turntable and proceed with scanning.
  
- +----- 
 + 
 + ====Einscan Quick Review==== 
 +Tool Lead:    \\ 
 +Contact: andrewfurst@ucsb.edu      \\ 
 +====Safety Concern====  
 +  * Lab coat and gloves must me used when handling resin  
 +  * Anything with uncured resin must be transported within a container to avoid spilling  
 + 
 +====Safe Operation Procedures Review==== 
 +  - Check resin cartridge and tank, make sure build material matches and is desired material. 
 +  - If resin is not desired material, disconnect wiper at build tank, remove build plate by sliding towards front of fume hood. Remove cartridge, cap valve on bottom and close valve on top of cartridge. Replace build tank, wiper, and cartridge with desired material.  
 +  - Launch Preform on Ultimaker computer 
 +  - Import desired STL 
 +  - Select "one click print" in the top left corner menu, change position, orientation, resolution and support as desired (note: that Preform will report on print ability of model, changing part rotation can affect print ability. 
 +  - Select print (orange button) from top left menu 
 +  - Select desired printer 
 +  - Press button on Formlabs printer to start print  
 + 
 +====Post Processing==== 
 +  - Excess resin should be removed from the build tray and part with IPA over a waste container.  
 +  - Place build tray and part in the Form Wash for 20 to 30 minuets (part can be placed individually within basket if necessary 
 +  - Allow 30 minuets for IPA to evaporate before placing part in Form Cure 
 +  - Set Form Cure time and temperature based on resin type, place part within form cure, wait for time to elapse 
 + 
 +====Maintenance==== 
 +  * Switching resin types 
 +    * Close breather valve on resin cartridge 
 +    * Resin cartridge by pulling straight up on the handle behind the form labs printers  
 +    * Cap the cartridge valve using the included orange tap and cap 
 +    * Remove the wiper by pulling straight out towards the front of the fume hood.  
 +    * Pull the resin tray out of the printer by pulling firmly straight out toward you 
 +    * Lift the wiper and resin tray out simultaneously, and carefully place on resin shelf within fume hood. 
 +    * Cover resin tray with black plastic cover and label 
 +    * Replace resin tray with clean or desired resin tank. Push tank and wiper firmly back toward the Form 2 until it clicks into place  
 +    * Replace resin cartridge and open valve 
  
  
  