Prop open the leftmost set of bunker doors. Maneuver the gas dolley inside the bunker until it is in front of the full tanks.
Identify the new bottle to be retrieved. The Cyl # is needed to check the cylinder out (Do not take any cylinders without an orange tag).
Open the gas bunker binder to the Checking Out Bottles section.
Find your Cyl # in the leftmost column of the binder. Do not enter your information in any row besides the one corresponding to the cylinder. Research groups go through gas at vastly different rates, so it may be a few pages behind.
Fill out all columns in the binder. Return the binder to the storage case on the wall with the pen.
Retrieve cylinders from the bunker and load onto the dolley. If you move any cylinders to access yours, make sure that they are secured with both chains when done.
Secure the tanks on the dolley using two points of contact (chain and safety strap most likely).
Carefully roll out dolley over the ledge. Park the dolley away from the bunker in a low energy state, and confirm it is not rolling before doing the next step.
Confirm that the key is in your possession, and close both bunker doors. Confirm that they are fully closed, otherwise they will not automatically lock.
Return the key to the safe, close it, and lock it. Enter the return time on the key sign out sheet.
Call the freight elevator (press down button, and when light is shining through the small gridded window, hold Door Open until the elevator doors are fully open. The elevator cannot be called if the doors are open on another floor.
Wheel the dolley inside the elevator, select the third floor button, and then step outside the elevator.
Hold Door Close until the elevator door is fully closed, then the bottle will be sent to the third floor.
Take the stairs or the personal elevator up to the third floor, and hold Door Open until the freight doors are fully open.
Wheel the gas canisters out, and then hold Door Close as a courtesy for others using the freight elevator.
Carefully navigate the dolley around the equipment in Microfluidics lab. Position the dolley close to the gas racks and rotate the cylinder into place.
Confirm the cylinder is chained at both points before returning the dolley to its storage place.