=====Gaucho Racing 2024 HV Battery SOP===== Last Updated: 1/22/24 Jason \\ This SOP provides a guide to safely manufacture and assemble battery segments of the GR23 electrical vehicle. Some of the information is compiled from the following sources. * [[https://drive.google.com/file/d/1WaE5zUF_ONd5w97KBsFAAIgpMukKw4gw/view?usp=sharing|Electrical Insulating PPE Guide]] * [[https://drive.google.com/file/d/10a0mtayN_YjYS8mw8pcqEAQBuuY6iT1I/view?usp=sharing|NFPA 70E PPE]] ====Overview==== * Safety considerations, how they can occur, and how to avoid electrical accidents * Battery segment design * Necessary materials, tools, and equipment * Opening the battery shipment box * Handling li-ion cells * Storing the ====Safety Considerations==== *Electrical shock & arc flash *There are two primary ways that direct current electrical injury can occur: -Body completing the loop in a high voltage circuit (touching positive and negative terminals of a high potential battery segment) -Non-insulated tool or a conductive material completes the circuit in a medium to high voltage circuit, generating an explosive arc that can produce intense heat *Electrical Insulating PPE *Referencing this [[https://drive.google.com/file/d/1WaE5zUF_ONd5w97KBsFAAIgpMukKw4gw/view?usp=sharing|Electrical Insulating PPE Guide]] and [[https://drive.google.com/file/d/10a0mtayN_YjYS8mw8pcqEAQBuuY6iT1I/view?usp=sharing|NFPA 70E PPE]], working with electric potentials between 50-750VDC (GR23 battery segment is 110V max voltage, entire battery pack is 546V max voltage) requires: * electrically insulating class 00 gloves {{wiki:fsae:arcflashgloves.png?150}} * nonconductive safety glasses * [[https://www.mcmaster.com/7315A71/|insulated tools]] * long sleeve shirt & pants * closed toed shoes * [[https://www.mcmaster.com/6893T13/|electrically insulating mat]] * arc-flash face shield {{:wiki:fsae:arcflashfaceshield.png?200}} *Workspace *As mentioned above, ensure that no non-insulated tools can fall across battery terminals or be accidentally used (remove all non-insulated tools that are magnetically attached above the workbench) * Workspace and ground should be covered with electrically insulating mats *No machining of metals should occur while battery segment terminals are exposed *Machining Fiberglass *Machining fiberglass can produce fine resin and glass particles that can be harmful if inhaled *Keep particles contained in CNC router enclosure *Use vacuum attachment *Wear masks *Wipe up particles often ====Battery Segment Design==== {{:wiki:fsae:batterysegmentdraeing.png}} 26s5p li-ion cells per segment comprised of Enepaq 1x5p Sony VTC6 modules ====Necessary Materials, Tools, and Equipment==== *Electrical Insulating PPE *Referencing this [[https://drive.google.com/file/d/1WaE5zUF_ONd5w97KBsFAAIgpMukKw4gw/view?usp=sharing|Electrical Insulating PPE Guide]] and [[https://drive.google.com/file/d/10a0mtayN_YjYS8mw8pcqEAQBuuY6iT1I/view?usp=sharing|NFPA 70E PPE]], working with electric potentials between 50-750VDC (GR23 battery segment is 110V max voltage, entire battery pack is 546V max voltage) requires: * electrically insulating class 00 gloves * nonconductive safety glasses * insulated tools * long sleeve shirt & pants * closed toed shoes * electrically insulating mat * arc-flash face shield *Drill bits & end mills for insulation panel machining *Epoxy for assembling panels *Wires & solder ====Machining of insulation panels==== - Fixture panels, program cam, and set up tools on ShopBot Router referencing [[http://microfluidics.cnsi.ucsb.edu/wiki/doku.php?id=shopbotdesktoptrainingsop|ShopBot SOP]] {{:wiki:fsae:insulationcnc.jpg?400}} *Set up vacuum attachment and wear masks to minimize inhalation of fine fiberglass particles - File edges of panels to remove sharp glass fibers ====Assembly of Enepaq modules within insulation==== - Insert modules with correct polarities and use epoxy to bond base and side panels of segment {{:wiki:fsae:batterysegmentclamp.png}} - **Wear proper PPE (listed in safety considerations section); those without PPE should remain five feet away** and connect modules together using bolts and busbars * **Cover work surface and ground with electrically insulating mat and use insulated tools** * Attach voltage taps under bolt heads using solder if necessary (onto copper washers) * Attach temperature sensing wires to module xr connector - Route wires through holes in top panel - Connect voltage taps carefully and avoid short circuiting any modules {{:wiki:fsae:batterybusbarconnection.png}} - Bond top panels to enclose segment {{:wiki:fsae:batterysegmentclamp2.png}}